Product
Anybus .NET Bridge – PROFINET to .NET Bridge
Item number: AB9077-C

AB9077-C, Anybus .NET Bridge – PROFINET to .NET BridgeAB9077-CThe Anybus PROFINET to .NET Bridge converts PROFINET to C#, enabling you to connect any PROFINET PLC control system with any .NET solution on a PC., The .NET Bridge uses simulators and code generators to simplify integration.Connect OT and ITCode generator Maximum Performance with Streamer ModeSimulatorsThe .NET Gateways enable PLC control systems to connect with .NET solutions, integrating OT and IT.The Anybus .NET Bridge Code Generator creates C# files for the .NET programmer and PLC files for the PLC programmer according to a defined spreadsheet.For applications requiring minimum delay and maximum performance, the .NET Bridge can be used in streamer mode, where data streams are exchanged directly without any handshake.The configuration software includes two simulators — a PLC simulator for the .NET programmer and a .NET simulator for the PLC programmer.profinet

Document
Anybus .NET Bridge

As a .NET programmer, you can send and recieve messages to and from a PLC system that could be used to control a process., You can also collect data for statistics, analyses and maintenance. .NET Bridge™ Example use cases: • An ordering system in a computer needs to tell a robot to fetch something in a warehouse, • Communicate simulated data from a computer to a PLC during testing and commisioning, Availablilty PROFIBUS Order number AB9071 PROFINET Order number AB9077 EtherNet/IP Order number AB9078 EtherCAT Order number AB9079 The Anybus .NET Bridge acts as a translator between a function block in a PLC and a .NET object in a computer., Cont.

Document
Product Change Notification - Anybus Gateways

To this end, we would like to inform you of the changing life cycle and schedule for the following product(s)., Reason for Change Anybus Communicator Classic, X-gateways, Linking devices and .NET gateways are very successful, well established and field proven., Lifecycle policy: https://www.anybus.com/support/anybus-product-life-cycle _______________________________ Magnus Rönn Field Application Engineer Anybus Gateways Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Appendix Article number Product Description AB7001 Anybus Communicator DeviceNet AB7003 Anybus Communicator CANopen AB7006 Anybus Communicator ControlNet AB7008 Anybus Communicator CC-Link AB7010 Anybus Communicator Modbus-RTU AB7077 Anybus Communicator CC-Link IE Field Network AB7078 Anybus Communicator RS232/422/485 - PROFINET IRT AB7079 Anybus Communicator RS232/422/485 - IIoT AB7300 Anybus X-gateway CANopen Master-EtherCAT Slave AB7301 Anybus X-gateway CANopen Master-PROFIBUS DP-V1 Slave AB7302 Anybus X-gateway CANopen Master-DeviceNet Slave AB7303 Anybus X-gateway CANopen, Master-ControlNet Slave AB7304 Anybus X-gateway CANopen Master-CANopen Slave AB7305 Anybus X-gateway CANopen Master-Modbus-RTU Slave AB7306 Anybus X-gateway CANopen Master-EtherNet/IP 2-Port Slave AB7307 Anybus X-gateway CANopen Master-PROFINET IO Slave AB7308 Anybus X-gateway CANopen Master-Ethernet Modbus-TCP 2-Port Slave AB7311 Anybus Communicator CAN EtherCAT AB7312 Anybus Communicator CAN PROFIBUS DP-V1 Slave AB7313 Anybus Communicator CAN DeviceNet Slave AB7314 Anybus Communicator CAN ControlNet Slave AB7315 Anybus Communicator CAN CANopen AB7316 Anybus Communicator CAN Modbus-RTU AB7317 Anybus Communicator CAN PROFINET IO AB7318 Anybus Communicator CAN EtherNet/IP 2-Port Slave AB7319 Anybus Communicator CAN EtherNet Modbus-TCP 2-Port Slave AB7320 Anybus Communicator CAN PROFINET IRT AB7321 Anybus Communicator CAN CC-Link Slave AB7328 Anybus Communicator CAN - PROFINET IRT AB7329 Anybus X-gateway CANopen - PROFINET IRT AB7500 Anybus X-gateway PROFIBUS DP-V0 Master-PROFINET, PROFIBUS to .NET Bridge AB9077 Anybus PROFINET to .NET Bridge AB9078 Anybus Ethernet/IP to .NET Bridge AB9079 Anybus EtherCAT to .NET Bridge HMS-EN2MB-R EtherNet/IP to Modbus-TCP Linking Device HMS-EN2PB-R EtherNet/IP to PROFIBUS Linking Device HMS-EN2SE-R EtherNet/IP to Serial Linking Device, Product Change Notification - Anybus Gateways

Document
Startup Guide - .NET Bridge

covers how to install and configure the .NET Bridge., SD Card Slot (Currently not in use.) 3., Anybus .NET Bridge Startup Guide SP2292 1.3 en-US Configuration 15 (32) 5 Configuration 5.1 Configuring the .NET Bridge The .NET Bridge must be configured before it can be connected to the IT network and the industrial network and before network settings, such as IP addresses, can be changed., For more information about the LED status indicators, refer to LED Guide, p. 27 Anybus .NET Bridge Startup Guide SP2292 1.3 en-US Technical Specifications 19 (32) 7 Technical Specifications Order code AB9077C — Anybus .NET Bridge PROFINET AB9078–C — Anybus .NET Bridge EtherNet/IP AB9079–C — Anybus .NET Bridge EtherCAT AB9071–C — Anybus .NET Bridge PROFIBUS Dimensions 110•35•101 mm, 4,33•1,38•3,98" Weight 160 g, 0,35 lb Operating temperature -25 to +70 °C, -13 to +158 °F Storage temperature -40 to +85 °C, -13 to +185 °F Relative Humidity 5-95% noncondensing Protection class IP20, NEMA rating 1 Mounting DIN rail (35•7,5/15) or Wall mount Current consumption Typical: 150 mA @ 24 V DC Power consumption 24 V DC +/- 10% Certifications Refer to datasheet at www.anybus.com/support., Click the checkbox for Internal DHCP Server, then click OK.

Document
REACH

If you have any questions or require further clarification, please contact us., AB4468-C NO AB4474-B NO AB4483-C NO AB4500-C NO AB4554-C YES 4ac7ac58-3d19-4a7a-9f7f-caf7c52f77b0 AB4571-C NO AB4582-B YES cb91fcb6-4838-4f7b-8e9b-a05206c21f5e AB4611-C YES af8674e4-fad9-42f5-a1f8-69a3db22a8ee AB4613-B NO AB4622-C YES d5cccb01-53eb-4ba7-8ec4-e23b18a6883f AB4643-B NO AB4648-C YES 66617109-53b9-4368-99d4-1107e88c5ecb AB4698-C YES d137df4b-56ce-4b72-9dfe-f47ee1c3b3b0 AB4720-B NO AB4735-C NO AB4739-C NO AB4742-C YES c356f60b-2fb1-4aaf-bb3b-7866b41e048f AB4780-C YES d53fd21b-675b-4551-aa58-59c4c499af46 AB4804-C NO AB4805-B YES 29765699-0ef0-4be1-b050-b29c2baf540f AB4806-C YES 9325d034-4ca0-4b99-9bb3-8af505e32c83 AB4807-C NO AB4817-C YES 21ddfa41-93df-42c3-befd-8eb25db4f28f AB4863-C YES 5e6b6b7a-95b1-43db-8c55-24a7a899e893 AB4864-C NO AB5105-B YES 148a5370-be40-45ab-8570-b5810af0ef55 AB5051-B YES a6301d40-464b-487a-a9fa-b133f182ef88 AB5055-B YES d3fb9d34-17ff-4662-b9bf-baacff5cb56b AB5079-B YES 8666ae7e-d998-4062-b3e2-4473d0f36e17 AB5084-B YES, -4698-b5f4-b2ab78edfe77 AB6664-B YES ff071de6-84a1-4833-9add-3658f5e2220b AB6666-B NO AB6668-B NO AB6670-C NO AB6671-C NO AB6672-C NO AB6673-C NO AB6674-C NO AB6674-D NO AB6675-C NO AB6675-D NO AB6677-C NO AB6677-D NO AB6680-C NO AB6681-C NO AB6700-C YES 170883ac-ce99-4a81-baf9-253bb9367db1 AB6701-C YES f3c679b2-5ee7-41a7-8415-59ed91f0a5cb AB6703-C NO AB6703-D NO AB6703-E NO AB6704-C NO AB6704-D NO AB6704-E NO AB6705-C NO AB6705-D NO AB6705-E NO AB6707-C NO AB6707-D NO AB6707-D-224 NO AB6707-E NO AB6709-B NO AB6709-B-116 NO AB6709-C NO AB6710-E NO AB6711-E NO AB6712-E NO AB6734-E NO AB6735-E NO AB6737-E NO AB6738-E NO AB6739-E NO AB6742-C YES d0e146f8-9bea-4f80-9ad7-8e0c0eef1922 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD AB6776-C-112 NO AB6781-C YES a998b24c-516f-4816-aec5, -d185ceb78c23 AB6787-C-136 NO AB6790-C NO AB6791-C NO AB6792-C NO AB6794-C NO AB6799-C NO AB6826-C YES 7328cdd8-9411-4a6d-87f8-cf0f3270df48 AB6901-C NO AB6904-C YES ad4f724a-3b23-411b-b243-0723c8d286a0 AB6905-C NO AB6906-C NO AB6907-C YES ec8b44f3-df6b-4d2e-a5be-8584281f42fb AB6908-C NO AB6909-C YES a10fd425-21eb-48ba-a297-5f02b8e5ab0e AB6911-C YES 98d6b4fc-293b-4685-8c44-4985f3a0c83e AB6915-C NO AB6916-D-224 NO AB6928-C NO AB6929-C NO AB6930-C NO AB6938-C-139 NO AB6941-C NO AB6942-C NO AB6946-C NO AB6949-C YES ed975b2e-a338-42c3-8cf1-97816d8e6b3e AB6957-C NO AB6960-C YES 23922b73-ffb4-45d9-ba37-b4302e90ad37 AB6961-C YES a3d6b02b-15ab-4293-8ed9-e5c01790e796 AB6962-C YES 19d448c7-6ba4-477a-9894-f0c4ed569fce AB6963-C NO AB6964-C NO AB6965-C NO AB6969-B NO AB6989-B NO AB6991-C NO AB6992-C NO AB6996-C YES dff38214-2693-459e-99f9-64c5c9163ecc AB7000-C YES d3b0d921-5539-4bfd-84c2-842cd2d4688b AB7001-C YES 47ff4908-8c9d-4d51-b4d6-326179f1781f AB7002-B YES, -F YES a4ce7fb5-2207-4ddb-9f1c-1ce34b1b5e70 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD AB8002-C YES f5e6f9b6-93f7-4973-bec6-d29557f481b8 AB8027-C YES b873875d-9601-4d51-8eca-aa418450e8c7 AB9000-B YES e813dd44-e0ea-497f-b599-81b827a72aac AB9001-B YES 50839ba9-b1c5-4263-b8ce-83dc1c2e55dd AB9003-B YES c5da9b8d-c4f0-4167-af94-098648fcfe68 AB9004-B YES e06de0e5-e075-43f8-9d46-95300bf70482 AB9005-B YES 150951d5-0559-49d6-bbb0-bf92d3e56287 AB9006-B YES c8c72884-e078-463c-bb57-2e8c182439af AB9007-B YES da342e6d-3633-4c41-b0af-c1c9729812ef AB9008-B YES 95667a98-c96e-45c1-b9b0-6445045d62f1 AB9077-C YES 2b397200-5848-432d-af1f-aa55e3b6bd20 AB9091-C YES d31fe825-f5de-4627-b478-d6adc3ad2f52 AB9092-C YES 52d64023-87fb-407a-8433-520111eec8bc ABC03011-A YES 7363c868-36a0-4176-89b8-d5044877de94 ABC3000-A ABC06011-

Document
User Manual - .NET Bridge Streamer Mode

To connect to the .NET Bridge, click Connect to bridge. 5., To connect to the .NET Bridge, click Connect to bridge., SD Card Slot (Currently not in use.) 3., For more information about the LED status indicators, refer to LED Guide, p. 39 Anybus .NET Bridge User Manual SCM-1202-120 1.1 en-US Technical Data 32 (46) 7 Technical Data 7.1 Technical Specifications Order code AB9077C — Anybus .NET Bridge PROFINET AB9078–C — Anybus .NET Bridge EtherNet/IP AB9079–C — Anybus .NET Bridge EtherCAT AB9071–C — Anybus .NET Bridge PROFIBUS Dimensions 110•35•101 mm, 4,33•1,38•3,98" Weight 160 g, 0,35 lb Operating temperature -25 to +70 °C, -13 to +158 °F Storage temperature -40 to +85 °C, -13 to +185 °F Relative Humidity 5-95% noncondensing Protection class IP20, NEMA rating 1 Mounting DIN rail (35•7,5/15) or Wall mount Current consumption Typical: 150 mA @ 24 V DC Power consumption 24 V DC +/- 10% Certifications Refer to datasheet at www.anybus.com/support., Click the checkbox for Internal DHCP Server, then click OK.

Document
User Manual - .NET Bridge Message Mode

The C# and .NET folder contains both a .cs file and a .dll file., To connect to the .NET Bridge, click Connect and Initialize. 6., To connect to the .NET Bridge, click Connect and Initialize . 6., For more information about the LED status indicators, refer to LED Guide, p. 68 Anybus .NET Bridge User Manual SCM-1202-121 1.1 en-US Technical Data 50 (76) 8 Technical Data 8.1 Technical Specifications Order code AB9077C — Anybus .NET Bridge PROFINET AB9078–C — Anybus .NET Bridge EtherNet/IP AB9079–C — Anybus .NET Bridge EtherCAT AB9071–C — Anybus .NET Bridge PROFIBUS Dimensions 110•35•101 mm, 4,33•1,38•3,98" Weight 160 g, 0,35 lb Operating temperature -25 to +70 °C, -13 to +158 °F Storage temperature -40 to +85 °C, -13 to +185 °F Relative Humidity 5-95% noncondensing Protection class IP20, NEMA rating 1 Mounting DIN rail (35•7,5/15) or Wall mount Current consumption Typical: 150 mA @ 24 V DC Power consumption 24 V DC +/- 10% Certifications Refer to datasheet at www.anybus.com/support., Click the checkbox for Internal DHCP Server, then click OK.