Product
Anybus Wireless Bridge II Int. Ant. - Ethernet
Item number: AWB3000-B

AWB3000-B, Anybus Wireless Bridge II Int., Ant. - EthernetAWB3000-BThe Anybus Wireless Bridge II Ethernet enable you to reduce the cost of cables, due to wear and tear, by using Bluetooth® or Wi-Fi communication., With our high-end point-to-point and multi-point technology you can easily establish a secure wireless connection that will help you to reduce unplanned downtime due to cable replacement.No more unplanned downtimeEasy to get startedIT approvedSecureMotion wears out communication cables, connectors, and slip rings leading to unplanned downtime and high cost.No prior knowledge required due to the simplicity of connecting the bridges., The mode button makes it easy to establish bridge-to-bridge connections.Anybus Wireless technology enables you to establish a secure wireless connection without interfering with the running network.Anybus Wireless solutions adhere to all essential international security regulations, providing you and your customer with a sense of security and peace of mind., Anybus Wireless Bridge II Int.

Kb
How to ensure a reliable PROFIsafe communication with Anybus Wireless Bridge?

APPLICABLE PRODUCTS Anybus Wireless Bridge II AWB3000 AWB3010 Anybus Wireless Bolt AWB2000 AWB2030   PRE-REQUISITES - Firmware 2.05.02 or newer is required, The Bolt/Bridge can support 802.11r when used as clients, not when used as access points., The Bolt should be set up as "L2 MAC Clone" for use with Profinet/PROFIsafe., Only one single device behind each Bolt., /ext. antenna (AWB3000/AWB3010)        , How to ensure a reliable PROFIsafe communication with Anybus Wireless Bridge?

Document
HMS Security Advisory 2021-07-02-001 - Anybus FragAttacks

This means that several of the newly discovered design flaws have been part of Wi-Fi since its release in 1997., Fortunately, the design flaws are hard to abuse because doing so requires user interaction or is only possible when using uncommon network settings., Conclusion regarding Anybus products Anybus Wireless Bridge and Anybus Wireless Bolt based on ODIN-W2 are potentially vulnerable only to a subset of the attacks known as FragAttacks as listed below., Referenced part numbers AWB3000-B AWB3000-B- 10PACK AWB3003-B AWB3300-B AWB3010-B AWB3010-B- 10PACK AWB3100-B AWB3101-B AWB3110-B AWB3120-B AWB3130-B AWB3131-B AWB3132-B AWB2000-B AWB2000-B- 10PACK AWB2000-B- RJ45PACK AWB2001-B AWB2001-B- 10PACK AWB2300-B AWB2010-B AWB2010-B- 10PACK AWB2011-B AWB2011-B- 10PACK AWB2020-B AWB2020-B- 10PACK AWB2021-B AWB2021-B- 10PACK AWB2305-B AWB2306-B AWB2310-B AWB2400-B AWB2030-B AWB2030-B- 10PACK AWB2031-B AWB2031-B- 10PACK AWB2330-B AWB2401-B- 10PACK Severity / CVSS Score - HMS Recommendations HMS recommends to observe the HMS Security Advisory web www.hms-networks.com/cybersecurity for any news regarding these vulnerabilities., Page 2 of 2 HMSSAR-2021-07-02_001 HMS Security Advisory Report Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Product updates HMS will provide a firmware update to overcome the referenced vulnerabilities.

Kb
Anybus Wireless scan not finding Bluetooth devices

APPLICABLE PRODUCTS Anybus Wireless Bridge II - Ethernet (AWB3000 and AWB3010)  Anybus Wireless Bolt - Ethernet RJ45 PoE (AWB2030)  Anybus Wireless Bolt Serial (AWB2010)  Anybus Wireless Bolt CAN (AWB2020)  PRE-REQUISITES Connection to the Anybus Wireless device configuration page At least one Bluetooth device in discovery mode and within range IN THIS ARTICLE  Bolt Configuration Best Practices AT Commands Additional Info   BOLT CONFIGURATION BEST PRACTICES: There are some best practices for setting the Bolt up for Bluetooth connections., WLAN (WiFi) should be disabled if it is not being used to save valuable resources, like memory and wireless bandwidth., To disable WLAN, the ‘Enable’ check box in the ‘WLAN Settings’ section should be unchecked., AT COMMANDS: If a Bolt is scanning for a non-Anybus Bluetooth device and unable to find it, or getting the “Error, couldn’t scan for any Devices” error, it may be because the Bolt is only searching for other Anybus devices.  , The Bolt uses a device filter to only search for other Anybus devices by default., Anybus Wireless scan not finding Bluetooth devices

Kb
Troubleshooting Anybus Wireless Bolt/Bridge Setup With Easy Config

APPLICABLE PRODUCTS Anybus Wireless Bolt - Ethernet 18-pin (AWB2000) Anybus Wireless Bolt Serial (AWB2010) Anybus Wireless Bolt CAN (AWB2020) Anybus Wireless Bolt - Ethernet RJ45 PoE (AWB2030) Anybus Wireless Bridge II - Ethernet (AWB3000)   ISSUE / QUESTION / SYMPTOM After setting both devices to an appropriate Easy Config mode and waiting 120 seconds, the devices aren't configured as expected., Timing After applying an Easy Config mode, the device will wait 120 seconds to discover or be discovered by another Bolt/Bridge., For that reason, it can be helpful to connect both devices to a computer so that both can be configured in quick sequence.  , Location Both Bolt/Bridge devices must be positioned within range of each other., ADDITIONAL INFO Visit the Files and Documentation page for setup guides, manuals, and firmware updates: Anybus Wireless Bolt - Ethernet 18-pin (AWB2000) Anybus Wireless Bolt Serial (AWB2010) Anybus Wireless Bolt CAN (AWB2020) Anybus Wireless Bolt - Ethernet RJ45 PoE (AWB2030) Anybus Wireless Bridge II - Ethernet (AWB3000)  , Troubleshooting Anybus Wireless Bolt/Bridge Setup With Easy Config

Kb
IPConfig doesn't find Wireless Bolt or Bridge

APPLICABLE PRODUCTS Anybus Wireless Bridge II - Ethernet (AWB3000 and AWB3010)  Anybus Wireless Bolt - Ethernet RJ45 PoE (AWB2030)  Anybus Wireless Bolt LTE (AWB1500)  Anybus Wireless Bolt IoT (AWB1000)  Anybus Wireless Bolt Serial (AWB2010)  Anybus Wireless Bolt CAN (AWB2020)  ISSUE IPConfig does not find Wireless Bolt or Bridge   POSSIBLE CAUSES Make sure the latest version of IPConfig is installed: The latest version can be download here or from https://www.anybus.com/support.  , Make sure the utility is scanning the correct adapter/interface: Select the gear icon in the upper right-hand corner: A specific interface to scan with or all interfaces can be selected: When the Bolt/Bridge is found, it can be selected to change its IP configuration, if necessary, so that the web interface can be reached.  , Verify that the Bolt is powered on and the LEDs are lit up (these can be seen through the reset hole on the bottom of the Bolt)., In the Network Adapters list, other active adapters can be temporarily disabled (including WiFi): If the problem persists, the Bolt should be reset to it's default settings., The web interface should now be manually accessible using a browser., IPConfig doesn't find Wireless Bolt or Bridge

Document
CIP Safety Statement

 Page 1 of 1 Ver. 2 Head office: HMS Industrial Networks AB | Stationsgatan 37, SE-302 45 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Statement: Anybus Wireless Bridge and CIP Safety TM The Anybus Wireless Bridge II and Anybus Wireless Bolt [parts numbers: AWB2000, AWB2030, AWB3000, AWB3010] is compliant to transport CIP Safety on EtherNet/IP TM using WLAN or Bluetooth according to the guidelines given in The CIP Networks Library, Volume 5 CIP Safety, Chapter 2-3.1.3 Bridging Different Physical Layers., General comment about CIP Safety CIP Safety is an ”end-to-end” type of protocol and is therefore independent of underlying physical layers such as Wireless LAN or Bluetooth.

Document
PROFIsafe Statement

 Page 1 of 1 Ver. 1 Head office: HMS Industrial Networks AB | Stationsgatan 37, SE-302 45 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Statement: PROFIsafe with Anybus Wireless Bridge II and Anybus Wireless Bolt The Anybus Wireless Bridge II and Anybus Wireless Bolt [parts numbers: AWB2000, AWB2030, AWB3000, AWB3010] is approved to transport PROFIsafe data over PROFINET using WLAN or Bluetooth according to the guidelines given in the PROFIsafe profile version 2.6.1 – Date August 2014 Order No.: 3.192, Profile part, related to IEC 61784-3-3, Edition 3., There shall be an encrypted access like https, or the configuration interfaces shall be switched off., Anybus wireless products can be configured to comply with the needs for PROFIsafe compatibility., The AT-command AT*AMPSM “PROFIsafe Mode” can be used to activate the PROFIsafe mode., Black Channel approach according to the PROFIsafe profile section 9.8.1 Wireless transmission channels are classified to be part of the "black channel" and thus do not need to be assessed for safety as FSCP 3/1 (PROFIsafe protocol) is approved for a bit error probability up to 10e-2 on the wireless channel.

Document
Startup Guide - Anybus Wireless Bridge II

This equipment contains parts that can be damaged by electrostatic discharge (ESD)., Anybus ® Wireless Bridge II ™ Startup Guide SP2167 2.1 en-US Installation 10 (18) 3.4 MODE Button The MODE button can be used to restart or reset the unit as well as for selecting an Easy Config mode., Restart as access point and connect clients. 6 B C Bluetooth NAP 7 A B C WLAN AP Configure units in mode 4 as clients., Apply PROFINET optimization to both units. 10 B D (any) Apply PROFINET optimization and restart. 11 A B D (any) Enable PROFIsafe mode., Static IP Address 192.168.0.99 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.99 Internal DHCP Server Disabled DHCP Interfaces All Default WLAN Settings Operating Mode Client Channel Bands 2.4 GHz & 5 GHz Authentication Mode WPA/WPA2–PSK Channel Auto Bridge Mode Layer 3 IP forward MIMO AWB3000: Enabled AWB3010: Disabled Default Bluetooth Settings Operating Mode PANU (Client) Local Name [generated from MAC address] Connectable No Discoverable No Security Mode Just works Bluetooth LE Operating Mode: Disabled Connectable: No Discoverable: No Anybus ® Wireless Bridge II ™ Startup Guide SP2167 2.1 en-US Technical Data 15 (18) 5 Technical Data 5.1 Hardware Specifications Order code AWB3000 AWB3010 Wired Interface type Ethernet Antenna 3 internal antennas: 2.4 GHz 2.4 GHz MIMO 5 GHz 1 external antenna: 2.4 GHz + 5 GHz dual band Dimensions (LxWxH) 93 x 68 x 33.2 mm Weight 120 g Operating temperature -40 to +65 °C Storage temperature -, Startup Guide - Anybus Wireless Bridge II

Document
User Manual - Anybus Wireless Bridge II Ethernet

Layer 3 IP forward = IP data will be bridged over Bluetooth., Bluetooth must be enabled on the Bluetooth Settings page to use Bluetooth LE., The result codes will be displayed below the text box., Anybus ® Wireless Bridge II ™ User Manual SCM-1202-032 2.4 en-US Configuration 28 (46) 4.4 Factory Restore Any one of these actions will restore the factory default settings: • Clicking on Factory Restore on the System Settings page • Executing Easy Config Mode 2 • Issuing the AT command AT&F and then restarting the unit • Holding MODE pressed for >10 seconds and then releasing it • Applying voltage to the digital input for >10 seconds Default Network Settings IP Assignment Static IP Address 192.168.0.99 Subnet Mask 255.255.255.0 Default Gateway 192.168.0.99 Internal DHCP Server Disabled DHCP Interfaces All Default WLAN Settings Operating Mode Client Channel Bands 2.4 GHz & 5 GHz Authentication Mode WPA/WPA2–PSK Channel Auto Bridge Mode Layer 3 IP forward MIMO AWB3000: Enabled AWB3010: Disabled Default Bluetooth Settings Operating Mode PANU (Client) Local Name [generated from MAC address] Connectable No Discoverable No Security Mode Just works, Anybus ® Wireless Bridge II ™ User Manual SCM-1202-032 2.4 en-US Appendix B: Technical Data 37 (46) B Technical Data B.1 Hardware Specifications Order code AWB3000 AWB3010 Wired Interface type Ethernet Antenna 3 internal antennas: 2.4 GHz 2.4 GHz MIMO 5 GHz 1 external antenna: 2.4 GHz + 5 GHz dual band Dimensions (LxWxH) 93 x 68 x 33.2 mm Weight 120 g Operating temperature -40 to +65 °C Storage temperature -40 to +85 °C Humidity EN 600068-2-78: Damp heat, +40 °C, 93 % humidity for 4 days Vibration See datasheet Housing material Plastic (see datasheet for details) Protection class IP65 Mounting Screw mount or DIN rail using optional clip Power connector M12 male A-coded Ethernet connector M12 female D-coded Power supply 9–30 VDC (-5 % +20 %) Cranking 12 V (ISO 7637-2:2011 pulse 4) Reverse polarity protection Power consumption 0.7 W (idle), 1.7 W (max) Anybus ® Wireless Bridge II ™ User Manual SCM-1202-032 2.4 en-US Appendix B: Technical Data, User Manual - Anybus Wireless Bridge II Ethernet

Document
REACH

-a2b2-e114ddb7301b 021590-B YES a6861920-6e60-4166-b07b-36b7a5c1b85f 021603-B YES 2a108c0a-c532-4c3f-b143-adc10c98ac64 021620-B YES fb353710-b65d-4343-9706-3a14128e8060 021630-B YES ab38b798-c2bf-411b-ab83-6129b0f6d251 021640-B NO 021650-B NO 021830-B YES 63923c55-bd51-4c7a-91ed-6394e02765bc 022190-B NO 022195-B NO 022400-B YES eb381208-de59-4d3b-9279-38946b520373 023040-B YES 3c56f67e-613a-4d1e-8633-b65d12af660e 023200-B YES 7e9153a2-d6a7-4ae4-b99d-f7774b8fbb26 023210-B YES 47595847-bb49-4b67-9162-3bc4eb69396f 023220-B YES eda90a42-f870-4874-aabd-8a8bdde53d77 024040-C NO 024070-B NO 024070-C NO 024720-B NO 024490-B NO 024590-B NO 024620-B YES 427e06e6-3327-40d4-8c83-87aa2b583efd 024707-B YES e870c102-70e0-4ccc-8525-d5d79fd02ada 028810-B NO 028841-B YES dd14e616-8fd6-431b-89f1-e265c26e679f 028851-B YES 5b6cd995-691b-4403-b58e-2f2c42705007 029300-B YES 4427c983-8ef0-4996-aeb8-8a69cc348c33 029630-B YES 3310961f-f126-424e-b810-c6f0160b93b5 1.01.0067.44010 YES, -17ff-4662-b9bf-baacff5cb56b AB5079-B YES 8666ae7e-d998-4062-b3e2-4473d0f36e17 AB5084-B YES 546bf8fb-1611-47f0-9be4-464cd4598726 AB5086-B YES be075e93-2e59-4ba8-9037-e45d7e3447b9 AB5095-B YES c2e070d8-28a8-4521-806b-b3701ab03e40 AB6000-B YES f6e3bfe8-bcc3-486d-8cbf-38e395de254a AB6001-B YES df68e007-266f-440d-94cc-992837773c2c AB6003-B YES 950f5f98-99b7-4cf8-b1bf-80cf1323ee16 AB6013-B YES b6ff54aa-ed17-4c94-b2e1-ecfe499f8b60 AB6021-B YES b7c80bcf-cdeb-4f83-8ed1-4e9999075071 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD AB6200-B YES 0ab1014a-9182-46f6-9d32-60b7c0e2ce85 AB6201-B YES de1a27bc-aa94-4f57-80ae-de95a74230ad AB6203-B YES 1b00b61c-917d-4ef9-8e53-a2882ed3af28 AB6207-B YES c08fcb26-cac7-404d-ae70-58730a8c10fb AB6208-B YES a85d87a0-7869-40ce-8ab2-ffd597c2e562 AB6211-B YES 9609fb4b-18a7-4adb-91fb-b3f0914584b9, AB6212-B YES 38cf0bd0-e04d-40cc-9258-4c421c4a817b AB6213-B YES 1be366e7-2f11-403f-bbcd-c08c99cd5978 AB6214-B YES e8aa9ee4-7a07-4e42-a310-bb6c6c53ef81 AB6215-B YES cd129746-485a-43f5-ab27-21dd3f32dc1e AB6216-B YES b9286b9f-c658-432b-a1d8-d1562948ad61 AB6218-B YES cda30450-e006-4477-94e9-da9791160df1 AB6220-B YES 0363d8a2-49ab-44fd-9771-30c8dabc154d AB6221-C NO AB6223-B NO AB6224-B NO AB6226-B NO AB6227-B NO AB6253-B YES e09ffa27-c2c0-4da1-8f60-c6a4b9e8d9c9 AB6300-B YES e99ca5e6-b0ea-4141-8e2b-43f2def0201d AB6301-B YES c38d72b8-a0e3-4169-9fe7-140b3493de3a AB6303-B YES b44d87aa-ff52-4a58-9a43-8c2774a93b2e AB6308-B YES 2dfb9bc3-002a-4567-8989-aa82c4a9038f AB6311-B NO AB6313-B YES 3fad52e7-9b49-4792-8096-a1a97b5bf703 AB6314-B YES 264e284d-0a50-4b28-aafb-2b4ab10d5ca3 AB6315-B YES 2a650cd5-2019-4966-b55a-f492e78900e5 AB6316-B NO AB6318-B YES d6957733-b253-4331-bc57-236a99efb57b AB6320-B YES 10bbcfbc-e839-4d93-a6b0-2a72a7901625 AB6321-C NO AB6324-B NO AB6352-B YES, ABC4090-A ABE04001-B YES b42e6749-74a6-49a0-be53-0d27c24af8a3 ABE04005-B YES 6944540f-00df-4cd3-b461-2f92a904764d ABE04020-B YES d5cc4c0b-1e7a-483a-a73d-3135389f4e11 ABE04032-B YES 9fbf1997-ad58-4aa2-925f-6088b8415181 ABE04044-B YES 304584fd-b964-4342-a9af-cd22c296b917 ABE04050-B YES b346b791-c393-4ce1-8e5b-c120ff65333d ABE04053-B YES 447e72cd-5bfa-4410-877a-aeb96fd7a390 ABE04062-B YES 813a1316-0e78-4dd7-bcd6-62cce0410a1b ABE04063-B YES 6317513b-cf97-4bbf-a358-52a46572a50b ABE04225-B YES d7b69600-1fc3-413a-98ca-92fef0eb9878 ABE04341-B YES 456fd2e1-1b82-4103-8e2e-4a10602eb3da ABE71105-B YES e1fda975-7aa7-4d4b-9603-114a0cd17522 ABE71106-B YES f0fada78-3c12-4f23-985b-601ba7bf402c ABE71301-B YES 623044a2-16ec-43ad-ab70-aa9a3f2be93f ABE71302-B YES daa0c61b-1916-4c3f-bc0d-b886b87f77d9 ABE71303-B YES 9ad30446-cbea-4e60-800b-9febc56fb3b2 ABE71304-B YES b9d1ef92-c4bf-4020-98a5-11059b08843f AC6133C_00MA YES 6c504dfc-bee2-4e14-899f-f94df5f300ff AC6133D_01MA YES 9e99bcd7-b2ee-4541, AWB2400-B YES 0613a33a-976a-4569-9832-5522ae3dba4d AWB3000-B YES bf6755c3-3012-4454-8dcb-643313f5b697 AWB3010-B YES 172130d1-d210-47fc-b0ae-57d2c0578a02 AWB3100-B YES 56540eaf-2be1-4a72-8ae3-5d9bbf58295f AWB3110-B YES 97921736-a8ba-40be-ad50-05408ca4e984 AWB5300-A YES bfb4894e-3be6-4be7-bc75-857aae4a6049 AWB6000-A AWB6001-A YES 3071d031-d737-4ff5-935e-df13ab18e678 AWB7000-A YES 1ab176f9-29a7-4fc0-90c6-a6f69759b42e E-022 YES 7d76043e-e9f5-4c41-86c0-77a79defb43c EC61330_00MA YES 9fe5b1ad-42eb-48c4-af10-b16a46000843 EC6133C_00MA YES 52938cd8-9359-4985-b831-8361a5edcbfe EC6133D_01MA YES 70716f3a-0552-4d5d-b2fb-10d0e7c7f605 EC6133F_00MA YES aa8777ee-4c7c-4460-97cf-a16587f06869 EC6133G_00MA YES c85af075-5d5f-429a-96f8-81fa66c89aea EC6133H_00MA YES 15ee29e2-ef17-47d5-bea7-681714156c2e EC71330_00MA YES 3daf240b-8bb0-45df-851d-d4418b9deffc EC7133J_00MA YES 477e0e5c-5311-406f-9fc9-fe9a1f0b8614 EC7133L_00MA YES ff475f1f-7f4b-43a4-8174-aa0d1d24fb12 FAC90501_0100 YES 8d006c9f-fdda

Document
Rockwell solution brochure

It allows both Modbus RTU and Modbus TCP signals show up as individual BACnet objects on any BACnet/IP or BACnet MS/TP network., This enables central control and supervision of Modbus devices from a BACnet Building Monitoring System (BMS)., Bridge and Bolt work together seamlessly!, The Wireless Bridge is often used in pairs but can also be used as an access point connecting up to 7 clients, Part No: AWB3000: Ethernet bridge via Bluetooth and WLAN Part No: AWB3010: Ethernet bridge via Bluetooth and WLAN (External antenna) Included components: Quick start guide, manuals., Rockwell solution brochure