HMS-EN2SE-R, Anybus EtherNet/IP Linking Devices – EtherNet/IP to Serial Linking DeviceHMS-EN2SE-RThe Anybus EtherNet/IP to Serial Linking Device converts serial to EtherNet/IP, enabling you to connect any serial device to a Logix PLC control system., No need for extra 3rd-party software, licenses, or programming.The Linking Device can convert any standard serial protocol such as Modbus RTU, DF1, or any other Request/Response or Produce/Consume proprietary protocol.EtherNet/IP Linking Devices are configured using a Custom Add-On Profile in Studio 5000, dynamically generating data structures for each device and eliminating the need for ladder logic files.Our Custom Add-On Profile for Studio 5000 supports the automatic generation of named and structured controller tags, eliminating the need to create alias tags.ethernetip
Although, the HMS-EN2SE-R Serial Linking Device supports up to 500 bytes of Input data and 496 bytes of Output data, there is a limitation on the number of transactions it supports. , APPLICABLE PRODUCTS Anybus Linking Device (HMS-EN2SE-R) PRE-REQUISITES RSLogix/Studio 5000 20.01 or greater IN THIS ARTICLE Issue Possible Causes Troubleshooting Steps Issue: RSLogix Error: “Configuration file exceeds maximum length., A Query/Response transaction uses the memory space of two transactions as there is a Query transaction and a Response transaction. , T ransactions where sequential memory space is being read or written to can be combined., For example, if there are 3 registers that are being read, 10 through 12, instead of using 3 transactions reading one word each, one transaction reading 3 words can be used instead. , HMS-EN2SE-R configuration file exceeds maximum length
This article explains the limitations of the Anybus Linking devices and alternatives when RSLogix / Studio 5000 cannot be used for configuration. , APPLICABLE PRODUCTS Anybus Linking Devices (HMS-EN2SE-R, HMS-EN2MB-R, HMS-EN2PB-R) PRE-REQUISITES This Guide assume you have the following hardware and software installed: RSLogix / Studio 5000 version 20.01 or newer Anybus Linking Device How can I configure my Linking Device without RSLogix 5000?, RSLogix / Studio 5000 version 20.01 or newer is required to configure these devices., What can I do if I can’t use RSLogix 5000?, The following devices can be substituted when RSLogix cannot be used: AB7072 for HMS-EN2SE-R (We have a new Serial Communicator here: ABC3007) AB9006 for HMS-EN2MB-R AB7800 for HMS-EN2PB-R ADDITIONAL INFO Anybus Linking Devices Anybus Gateway Index , How to configure Anybus Linking Device without RSLogix / Studio 5000
EU - Declaration of Conformity The Manufacturer: HMS Industrial Networks AB Stationsgatan 37 SE-302 50 Halmstad Sweden www.hms.se Declares under our sole responsibility that the product: are hereby declared in conformity with essentials requirements of the following EU Directive(s) when installed accordingly with the installation instructions: 2014/30/EU EMC Directive (Electromagnetic Compatibility) 2011/65/EU RoHS Directive with amendment 2015/863 Type of Products: Industrial gateways Models: Options: Anybus X-gateway Modbus/TCP Profibus, DeviceNet, Ethernet/IP, EtherCAT, Modbus-RTU, CC-Link, ControlNet, Profinet, Modbus-TCP, CANopen Models: Options: Anybus Communicator CANopen, CC-Link, ControlNet, DeviceNet, EtherCAT, EtherNet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet- IRT, OPC-UA, MQTT Models: Options: Anybus Communicator CAN CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, , Profibus, Profinet-IO, Profinet IRT, CC-Link Models: Options: Anybus X-gateway ASI, CANopen, CC-Link, CC-Link Field Network, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT, Powerlink, OPC-UA, MQTT Models: Options: Anybus X-gateway DeviceNet, Anybus BridgeWay DeviceNet Ethernet, Profibus Models: Options: Anybus X-gateway – Ethernet Modbus TCP slave – Modbus RTU Master - Models: Options: Anybus X-gateway – CANopen Master/slave CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT Models: Options: .NET bridge series Profinet, EtherCAT, Ethernet/IP, Profibus Models: Options: HMS-EN2MB-R - Models: Options: HMS-EN2PB-R - Models: Options: HMS-EN2SE-R - References to relevant harmonized standards used or references to the specifications in relation to which conformity is declared: Conformity to standards
Description 1 +5V OUT 2 RS232 Rx 3 RS232 Tx 4 NC 5 Signal GND 6 RS422 Rx+ 7 RS422 Rx- 8 RS485+ / RS422 Tx+ 9 RS485- / RS422 Tx- PC Connector: Not used Power: 1. +24 V DC 2., GND Accessories Checklist The following items are required for installation: • Subnetwork connector • Ethernet cable and connector (not included) Installation and Startup Summary • Mount the EN2SE-R linking device on the DIN-rail, • Search in the catalogue for the HMS-EN2SE-R, EtherNet/IP Connectors Pin no Description 1 TD+ 2 TD- 3 RD+ 4 Termination 5 Termination 6 RD- 7 Termination 8 Termination 1 8 LED Indicators LED Indication Description 1 (Module Status) Off Green Flashing Green Flashing Red Red Flashing Green/Red No power Controlled by a scanner in run state Not configured, or scanner in idle state Minor fault (recoverable) Major fault (unrecoverable) Self-test in progress 2 (Network Status) Off Green Flashing Green Red Flashing Red Flashing Green/Red No IP address, or no power Online, one or more EtherNet/IP connec- tions established Online, no connections established Duplicate IP address detected., • ATTENTION – RISQUE D’EXPLOSION – EN ZONE EXPLOSIVE, VEUILLEZ COUPER L’ALIMENTATION ÉLECTRIQUE AVANT LE REMPLACEMENT OU LE RACCORDEMENT DES MODULES
UK - Declaration of Conformity The Authorised Representative: The Manufacturer: HMS Industrial Networks Ltd The Venture Centre, Sir William Lyons Road Warwick University Science Park Coventry CV4 7EZ, UK HMS Industrial Networks AB Stationsgatan 37 SE-302 50 Halmstad, Sweden www.hms.se Declares under our sole responsibility that the product: Is hereby declared in conformity with essentials requirements of the following UK Legislation(s) when installed accordingly with the installation instructions: • Electromagnetic Compatibility Regulations 2016 • The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 Type of Products: Industrial gateways Models: Options: Anybus X-gateway Modbus/TCP Profibus, DeviceNet, Ethernet/IP, EtherCAT, Modbus-RTU, CC-Link, ControlNet, Profinet, Modbus-TCP, CANopen Models: Options: Anybus Communicator CANopen, CC-Link, ControlNet, DeviceNet, EtherCAT, EtherNet/IP, FIPIO, Interbus, , LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet- IRT, OPC-UA, MQTT Models: Options: Anybus Communicator CAN CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet IRT, CC-Link Models: Options: Anybus X-gateway ASI, CANopen, CC-Link, CC-Link Field Network, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT, Powerlink, OPC-UA, MQTT Models: Options: Anybus X-gateway DeviceNet, Anybus BridgeWay DeviceNet Ethernet, Profibus Models: Options: Anybus X-gateway – Ethernet Modbus TCP slave – Modbus RTU Master - Models: Options: Anybus X-gateway – CANopen Master/slave CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT Models: Options: .NET bridge series Profinet, EtherCAT, Ethernet/IP, Profibus Models: Options: HMS-EN2MB-R, - Models: Options: HMS-EN2PB-R - Models: Options: HMS-EN2SE-R - References to relevant designated standards used or references to the specifications in relation to which conformity is declared: Conformity to standards: EN 61000-6-4:2007 + A1:2011 Emission standard for industrial environment EN 55016-2-3:2017 (Class A) EN 55032:2015 (Class A) EN 61000-6-2:2019 Immunity for industrial environment EN 61000-4-2:2009 EN 61000-4-3:2006 + A1:2008 + A2:2010 EN 61000-4-4:2012 EN 61000-4-5:2014 + A1:2018 EN 61000-4-6:2014 Coventry, February 23rd, 2022 David Bradley-Folley, General Manager at HMS Industrial Networks Ltd _________________________________
EU - Declaration of Conformity The Manufacturer: HMS Industrial Networks AB Stationsgatan 37 SE-302 50 Halmstad Sweden www.hms.se Declares under our sole responsibility that the product: Are hereby declared in conformity with essentials requirements of the following EU Directive(s) when installed accordingly with the installation instructions: 2014/30/EU EMC Directive (Electromagnetic Compatibility) 2011/65/EU RoHS Directive with amendment 2015/863 Type of Products: Industrial gateways Models: Options: Anybus X-gateway Modbus/TCP Profibus, DeviceNet, Ethernet/IP, EtherCAT, Modbus-RTU, CC-Link, ControlNet, Profinet, Modbus-TCP, CANopen Models: Options: Anybus Communicator CANopen, CC-Link, ControlNet, DeviceNet, EtherCAT, EtherNet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet- IRT, OPC-UA, MQTT Models: Options: Anybus Communicator CAN CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, , Profibus, Profinet-IO, Profinet IRT, CC-Link Models: Options: Anybus X-gateway ASI, CANopen, CC-Link, CC-Link Field Network, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT, Powerlink, OPC-UA, MQTT Models: Options: Anybus X-gateway DeviceNet, Anybus BridgeWay DeviceNet Ethernet, Profibus Models: Options: Anybus X-gateway – Ethernet Modbus TCP slave – Modbus RTU Master - Models: Options: Anybus X-gateway – CANopen Master/slave CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT Models: Options: .NET bridge series Profinet, EtherCAT, Ethernet/IP, Profibus Models: Options: HMS-EN2MB-R - Models: Options: HMS-EN2PB-R - Models: Options: HMS-EN2SE-R - References to relevant harmonized standards used or references to the specifications in relation to which conformity is declared: Conformity to standards
Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD REACH Statement EU Regulation (EC) 1907/2006, REACH REACH (Registration, Evaluation, Authorization and Restriction of Chemicals, EC 1907/2006) is the European Union’s (EU) chemical substances regulatory framework., HMS is aware of the REACH regulations, potential implications to our business and our obligations to make relevant actions to enable business continuity., Article 7 – Registration With regard to Article 7(1) of the REACH regulation, articles produced by HMS do not contain substances intended to be released under normal or reasonably foreseeable conditions of use and do not contain any Substances of Very High concern (SVHC) that exceed 1 ton per year., HMS has reviewed the latest Restriction List and declares that all supplied products meet the conditions for use and are thus compliant with Annex XVII., HMS reserves the right to change the information stated in this document without any further notice., REACH, HMS
EU - Declaration of Conformity The Manufacturer: HMS Industrial Networks AB Stationsgatan 37 SE-302 50 Halmstad Sweden www.hms.se Declares under our sole responsibility that the product: Are hereby declared in conformity with essentials requirements of the following EU Directive(s) when installed accordingly with the installation instructions: 2014/30/EU EMC Directive (Electromagnetic Compatibility) 2011/65/EU RoHS Directive with amendment 2015/863 Type of Products: Industrial gateways Models: Options: Anybus X-gateway Modbus/TCP Profibus, DeviceNet, Ethernet/IP, EtherCAT, Modbus-RTU, CC-Link, ControlNet, Profinet, Modbus-TCP, CANopen Models: Options: Anybus Communicator CANopen, CC-Link, ControlNet, DeviceNet, EtherCAT, EtherNet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet- IRT, OPC-UA, MQTT Models: Options: Anybus Communicator CAN CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, , Profibus, Profinet-IO, Profinet IRT, CC-Link Models: Options: Anybus X-gateway ASI, CANopen, CC-Link, CC-Link Field Network, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT, Powerlink, OPC-UA, MQTT Models: Options: Anybus X-gateway DeviceNet, Anybus BridgeWay DeviceNet Ethernet, Profibus Models: Options: Anybus X-gateway – Ethernet Modbus TCP slave – Modbus RTU Master - Models: Options: Anybus X-gateway – CANopen Master/slave CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT Models: Options: .NET bridge series Profinet, EtherCAT, Ethernet/IP, Profibus Models: Options: HMS-EN2MB-R - Models: Options: HMS-EN2PB-R - Models: Options: HMS-EN2SE-R - References to relevant harmonized standards used or references to the specifications in relation to which conformity is declared: Conformity to standards
The content of this Declaration of Conformity is public information and this Declaration may be reproduced in whole, but not in parts, without modification., ODVA PUB00297R0 Declaration of Conformity (DOC) Reference Information File Number: 11458.01 Part 1of1 YearLastIssued: 2016 Length of Validity: Continues in effect so long as the named entity (i) remains an ODVA Licensed Vendor for the ODVA technology(ies) defined by the above specification(s); (ii) continues to fulfill its user responsibilities as defined in its Terms of Usage Agreement with ODVA; and (iii) the CIP Identity for the Product(s) remains identical to those enumerated in this Declaration of Conformity., ODVA Licensed Vendor to Whom this DOC Has Been Issued Entity Name: HMS Industrial Networks AB Vendor ID: 90 Overview of Compliant Product(s) Covered by This DOC (The list of product(s) covered by this DOC begins on page 2.), The content of this Declaration of Conformity is public information and this Declaration may be reproduced in whole, but not in parts, without modification., Vendor Product Code (attribute 3) Vendor Product Revision (attribute 4) Vendor Product Name (attribute 7) 1 88 4 .00 5 HMS-EN2SE-R
UK - Declaration of Conformity The Authorised Representative: The Manufacturer: HMS Industrial Networks Ltd The Venture Centre, Sir William Lyons Road Warwick University Science Park Coventry CV4 7EZ, UK HMS Industrial Networks AB Stationsgatan 37 SE-302 50 Halmstad, Sweden www.hms.se Declares under our sole responsibility that the product: Is hereby declared in conformity with essentials requirements of the following UK Legislation(s) when installed accordingly with the installation instructions: • Electromagnetic Compatibility Regulations 2016 • The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 Type of Products: Industrial gateways Models: Options: Anybus X-gateway Modbus/TCP Profibus, DeviceNet, Ethernet/IP, EtherCAT, Modbus-RTU, CC-Link, ControlNet, Profinet, Modbus-TCP, CANopen Models: Options: Anybus Communicator CANopen, CC-Link, ControlNet, DeviceNet, EtherCAT, EtherNet/IP, FIPIO, Interbus, , LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet- IRT, OPC-UA, MQTT Models: Options: Anybus Communicator CAN CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet IRT, CC-Link Models: Options: Anybus X-gateway ASI, CANopen, CC-Link, CC-Link Field Network, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, FIPIO, Interbus, LonWorks, Modbus Plus, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT, Powerlink, OPC-UA, MQTT Models: Options: Anybus X-gateway DeviceNet, Anybus BridgeWay DeviceNet Ethernet, Profibus Models: Options: Anybus X-gateway – Ethernet Modbus TCP slave – Modbus RTU Master - Models: Options: Anybus X-gateway – CANopen Master/slave CANopen, ControlNet, DeviceNet, EtherCAT, Ethernet/IP, Modbus-RTU, Modbus-TCP, Profibus, Profinet-IO, Profinet-IRT Models: Options: .NET bridge series Profinet, EtherCAT, Ethernet/IP, Profibus Models: Options: HMS-EN2MB-R, - Models: Options: HMS-EN2PB-R - Models: Options: HMS-EN2SE-R - References to relevant designated standards used or references to the specifications in relation to which conformity is declared: Conformity to standards: EN 61000-6-4:2007 + A1:2011 Emission standard for industrial environment EN 55016-2-3:2017 (Class A) EN 55032:2015 (Class A) EN 61000-6-2:2019 Immunity for industrial environment EN 61000-4-2:2009 EN 61000-4-3:2006 + A1:2008 + A2:2010 EN 61000-4-4:2012 EN 61000-4-5:2014 + A1:2018 EN 61000-4-6:2014 Coventry, February 23rd, 2022 David Bradley-Folley, General Manager at HMS Industrial Networks Ltd _________________________________
Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Product Change Notification Dear Partner, Anybus appreciates your daily involvement and your long-term loyalty., The need to continue to add new features is limited and as a result Anybus has decided to focus development efforts on newly released products., Lifecycle policy: https://www.anybus.com/support/anybus-product-life-cycle _______________________________ Magnus Rönn Field Application Engineer Anybus Gateways Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD Appendix Article number Product Description AB7001 Anybus Communicator DeviceNet AB7003 Anybus Communicator CANopen AB7006 Anybus Communicator ControlNet AB7008 Anybus Communicator CC-Link AB7010 Anybus Communicator Modbus-RTU AB7077 Anybus Communicator CC-Link IE Field Network AB7078 Anybus Communicator RS232/422/485 - PROFINET IRT AB7079 Anybus Communicator RS232/422/485 - IIoT AB7300 Anybus X-gateway CANopen Master-EtherCAT Slave AB7301 Anybus X-gateway CANopen Master-PROFIBUS DP-V1 Slave AB7302 Anybus X-gateway CANopen Master-DeviceNet Slave AB7303 Anybus X-gateway CANopen, Slave AB7856 Anybus X-gateway DeviceNet Slave-FIPIO Slave AB7859 Anybus X-gateway DeviceNet Slave-CANopen Slave AB7860 Anybus X-gateway DeviceNet Slave-Modbus-RTU Slave AB7862 Anybus X-gateway DeviceNet Slave-CC-Link Slave AB7864 Anybus X-gateway ControlNet Slave-ControlNet Slave AB7866 Anybus X-gateway ControlNet Slave-Interbus Slave AB7868 Anybus X-gateway ControlNet Slave-CANopen Slave AB7869 Anybus X-gateway ControlNet Slave-Modbus-RTU Slave AB7871 Anybus X-gateway ControlNet Slave-CC-Link Slave AB7894 Anybus X-gateway CANopen Slave-CANopen Slave AB7895 Anybus X-gateway CANopen Slave-Modbus-RTU Slave Date of Publication: 2024-01-22 Head office: HMS Industrial Networks AB | Stationsgatan 37, Box 4126, SE-300 04 HALMSTAD |www.hms-networks.com Phone: +46 35 17 29 00 | Fax: +46 35 17 29 09 | Mailing address: P.O BOX 4126, SE 300 04 HALMSTAD AB7897 Anybus X-gateway CANopen Slave-CC-Link Slave AB7899 Anybus X-gateway Modbus-RTU Slave-Modbus-RTU Slave AB7900 Anybus X-gateway, PROFIBUS to .NET Bridge AB9077 Anybus PROFINET to .NET Bridge AB9078 Anybus Ethernet/IP to .NET Bridge AB9079 Anybus EtherCAT to .NET Bridge HMS-EN2MB-R EtherNet/IP to Modbus-TCP Linking Device HMS-EN2PB-R EtherNet/IP to PROFIBUS Linking Device HMS-EN2SE-R EtherNet/IP to Serial Linking Device, HMS
HMS connectivity solutions are proven and trusted within Rockwell Automation installations worldwide., Temp 0 to +55 °C 0 to +85 °C Power 24 VDC +/-10% Isolation Yes on both sides Rating IP20 Mounting DIN-rail or Wall mount Connectors 2x RJ45 + 1 DSUB 9F Baudrates 10/100 + 1,2-57,6 kbit/s ConfigPorts 1x USB Certification CE, ATEX, Haz.Loc UL & cUL Guarantee 3 years SPECIFICATIONS HIGHLIGHTS Part No: HMS-EN2SE-R Installation guide, DSUB connector with screw terminals for sub-network (Power supply not included) Part No: 019570 (Optional) USB-RS232 configuration adapter ORDERING INFORMATION • Selectable RS-232/422/485 • Reduce long cable runs • No serial device HW/SW changes • Multi-drop upto 31 nodes (RS485) • Up to 10 EIP I/O connections • ODVA EIP conformance tested • Encompass Partner Product Integrate devices with almost any serial protocol to Logix PLCs ControlLogix PLC EtherNet/IP Device Level Ring (DLR) To p o l o g y H M S-EN2SE-R Linking Device with Announced-based DLR support Integrated Serial Master functionality Serial RS485 DF1 RS-232 The, HMS Industrial Networks Through the Anybus®, IXXAT® and eWON® brands and products, HMS Industrial Networks provides reliable solutions for industrial communication and remote connectivity., Part No: MMA500 Version 2 05/2017 - © HMS Industrial Networks - All rights reserved - HMS reserves the right to make modifications without prior notice., HMS - Sweden (HQ) Tel : +46 35 17 29 00 (Halmstad HQ) E-mail: sales@hms-networks.com HMS - China Tel : +86 10 8532 1188 E-mail: cn-sales@hms-networks.com HMS - France Tel: +33 368 368 034 (Mulhouse office) E-mail: fr-sales@hms-networks.com HMS - Germany Tel: +49 721 989777-000 E-mail: ge-sales@hms-networks.com HMS - India Tel: +91 83800 66578 E-mail: in-sales@hms-networks.com HMS - Italy Tel : +39 039 59662 27 E-mail: it-sales@hms-networks.com HMS - Japan Tel: +81 45 478 5340 E-mail: jp-sales@hms-networks.com HMS - Switzerland Tel: +41 61 511342-0 E-mail: ch-sales@hms-networks.com HMS - UK Tel: +44 1926 405599 E-mail: uk-sales@hms-networks.com HMS - United States Tel: +1 312 829 0601 E-mail: us-sales@hms-networks.com Distributed by:, Rockwell solution brochure, HMS