CAN/CAN FD repeater with four channels
Item number 1.01.0210.40200
The Ixxat CAN-CR300 repeater with four CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. It provides the flexibility to optimize network structures and liberates them from CAN bus structure constraints for optimized operation.
Designed for industrial environments, meeting high demands for robustness, temperature ranges, and safety.
Helps to optimize CAN/CAN FD network structures by enabling extended layouts (stub lines, star and tree topologies).
Minimal impact on real-time behavior, equivalent to a short line length (ca. 35 m/175 ns delay). Enabling transparent transmission, compatible with all higher layer protocols.
Optimized topologies enable simpler wiring, resulting in less cables and cost savings at installation and maintenance.
The CAN-CR300 ensures system reliability by electrically isolating CAN/CAN FD segments and power, auto-separating network faults and keeping the network operational.
In case of disturbances in the CAN lines, the repeater automatically disconnects the affected segment and restores it after the fault is resolved, ensuring uninterrupted network operation.
Using the CAN-CR300, network components can be galvanically isolated up to 1 kV. This reliably enhances the protection of the device against damage to electronics caused by voltage peaks.
Equipped with four CAN/CAN FD channels, the CAN-CR300 can be used to establish a physical coupling and galvanic isolation of two segments of both CAN and CAN FD bus systems.
CAN/CAN FD repeater with screw terminals
The Ixxat CAN-CR100 repeater with two CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. It provides the flexibility to optimize network structures and liberates them from CAN bus structure constraints for optimized operation.
CAN/CAN FD repeater with fiber optics
The Ixxat CAN-CR110/FO with two CAN/CAN FD interfaces, one of which is a Fiber Optic interface, enables the conversion of CAN signals from copper wire to fiber optics. It enhances connectivity in high-electromagnetic interference zones and provides the flexibility to optimize network structures.
CAN/CAN FD repeater with screw terminals and termination resistor
The Ixxat CAN-CR100 repeater with two CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. It provides the flexibility to optimize network structures and liberates them from CAN bus structure constraints for optimized operation. With integrated termination resistors.
CAN/CAN FD repeater with 3 kV galvanic isolation and termination
The Ixxat CAN-CR120/HV repeater with two CAN/CAN FD interfaces provides a galvanic isolation up to 3 kV for enhanced protection of network segments. It improves the CAN bus load capacity, establishes a physical coupling of bus systems and provides the flexibility to optimize network structures. With integrated termination resistors.
CAN repeater with fiber optics (ST) and backbone bus
The Ixxat CAN-CR210/FO repeater with two CAN interfaces, one of which is a Fiber Optic interface (ST plug), enables the conversion of CAN signals from copper wire to fiber optics. It enhances connectivity in high-electromagnetic interference zones and provides the flexibility to optimize network structures. With integrated CAN backbone interface.
CAN repeater with fiber optics (F-SMA) and backbone bus
The Ixxat CAN-CR210/FO repeater with two CAN interfaces, one of which is a Fiber Optic interface (FSMA plug), enables the conversion of CAN signals from copper wire to fiber optics. It enhances connectivity in high-electromagnetic interference zones and provides the flexibility to optimize network structures. With integrated CAN backbone interface.
CAN/CAN FD repeater with four channels
The Ixxat CAN-CR300 repeater with four CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. It provides the flexibility to optimize network structures and liberates them from CAN bus structure constraints for optimized operation.
CAN/CAN FD repeater with 3 kV galvanic isolation
The Ixxat CAN-CR120/HV repeater with two CAN/CAN FD interfaces provides a galvanic isolation up to 3 kV for enhanced protection of network segments. It improves the CAN bus load capacity, establishes a physical coupling of bus systems and provides the flexibility to optimize network structures.
CAN/CAN FD repeater with 4 kV DC/4 kV AC galvanic isolation
The Ixxat CAN-CR220 repeater with two CAN interfaces provides a galvanic isolation 4 kV DC/4 kV AC for 1 second, enhancing the protection of network segments. It improves the CAN bus load capacity, establishes a physical coupling of bus systems and provides the flexibility to optimize network structures. The CAN-CR220 meets DIN/EN 50178 standards.
CAN repeater with backbone bus
The Ixxat CAN-CR200 repeater with two CAN interfaces and one CAN backbone interface improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. Multiple repeaters can be lined up and connected easily via the integrated DINrail bus to create various topologies and optimize network structures.
CAN/CAN FD repeater with fiber optics and termination resistor
The Ixxat CAN-CR110/FO with two CAN/CAN FD interfaces, one of which is a Fiber Optic interface, enables the conversion of CAN signals from copper wire to fiber optics. It enhances connectivity in high-electromagnetic interference zones and provides the flexibility to optimize network structures. With integrated termination resistors.
CAN repeater with 4 kV DC/3.5 kV AC galvanic isolation
The Ixxat CAN-CR220 repeater with two CAN interfaces provides a galvanic isolation up to 4 kV DC/3.5 kV AC for 1 second, enhancing the protection of network segments. It improves the CAN bus load capacity, establishes a physical coupling of bus systems and provides the flexibility to optimize network structures. The CAN-CR220 meets DIN/EN 50178 standards.
CAN/CAN FD repeater with four channels and termination resistor
The Ixxat CAN-CR300 repeater with four CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. It provides the flexibility to optimize network structures and liberates them from CAN bus structure constraints for optimized operation. With integrated termination resistors.
Content of Delivery
CAN FD repeater, user manual
Net Width (mm)
105 mm
Net Height (mm)
114 mm
Net Depth (mm)
22.5 mm
Net Weight (g)
220 g
Mounting
DIN rail mount (bracket included)
Current Consumption Type Value at Vcc Nom (mA)
90
Current Consumption Max value at Vcc nom (mA)
125
Input Voltage (V)
+9 V to +36 V DC
Isolation
1 kV DC for 1 sec.
Operating Temperature °C Min
-20 °C
Operating Temperature °C Max
70 °C
Storage Temperature °C Min
-40 °C
Storage Temperature °C Max
85 °C
Relative Humidity
10 to 95 %, non-condensing
Housing Materials
Polyamide housing for top hat rail mounting
Packaging Material
Cardboard
CE
Yes
FCC
Yes
WEEE Category
IT and telecommunications equipment
ETIM Classification
EC000698
Protection Class IP
IP20
Connectors / Input / Output
4 x screw terminals, 1 x power connector
Contains Battery
No
Brand
Ixxat
Country of Origin
Sweden
HS Code
8517620000
Dual Usage
No
Export Control Classification Number (ECCN)
EAR99
Item Number
1.01.0210.40200
CAN Mode
CAN high-speed (ISO 11898-2) with CAN choke
CAN Baud Rate
Up to 1 Mbit/s
CAN FD Mode
ISO CAN FD, nonISO CAN FD
CAN FD Baud Rate
Arbitration rate up to 1000 kBit/s, data rate up to 8000 kBit/s (verified by testing). User defined bit rates are possible.
CAN FD Transceiver
MCP2562FD
Can't find a distributor or partner or need help to figure out which partner suits you?
No problem, you can always contact your nearest HMS office and let our sales and customer service staff take care of your enquiry.
To download this file you need to submit your email address. You will then get an email with the download link
Invalid email address
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
Ixxat All you need for CAN Brochure MMI119 (English)
|
6 | 4.7 MB |
dda14505-22ce-6706-92f4-ff00001bbfd4
Download
|
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
CAN CR100, CR110-FO, CR120-HV, CR300 - CE Declaration of Conformity
|
192.2 KB |
f4de2b05-22ce-6706-92f4-ff00001bbfd4
Download
|
Manuals
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
CAN-FD-Repeater CRxx Manual English
|
1.4 MB |
54de2b05-22ce-6706-92f4-ff00001bbfd4
Download
|
File | Product / versions | Filetype | Size | ||
---|---|---|---|---|---|
In the drawing all plugs are equipped. Not used plugs must be removed.
|
Step 3D file for CAN-CR1x0, CAN-CR300
|
stp | 10.9 MB |
45289905-22ce-6706-92f4-ff00001bbfd4
Download
|
Training from HMS Academy reduces the total cost and time of your project and gives improved quality and efficiency of the solution.
HMS offers trainings related to products, technologies and more. This could be in the form of an onsite training, online training or by running one of our E-learning sessions.
Technical Services from HMS helps customers with any type of assistance needed in addition to the products bought from HMS. The Technical Services page offers a list of all services we provide.
The services are provided by HMS’ global team of skilled and experienced engineers who work together with you, providing various services.
Typical activities are project planning, setting up evaluation demos, creating and validating product configurations, providing guidance during field trials, and more.
Technical Services from HMS helps customers with any type of assistance needed in addition to the products bought from HMS. The Technical Services page offers a list of all services we provide.
The services are provided by HMS’ global team of skilled and experienced engineers who work together with you, providing various services.
Typical activities are project planning, setting up evaluation demos, creating and validating product configurations, providing guidance during field trials, and more.